Nighthawk Manuals; Carbon Monoxide Alarm; KN-COP-DP; Nighthawk KN-COP-DP Manuals Manuals and User Guides for Nighthawk KN-COP-DP. We have 1 Nighthawk KN-COP-DP manual available for free PDF download: User Manual.
- A carbon monoxide detector can save your life, but only if it's functioning properly. If you suspect your Kidde Nighthawk carbon monoxide alarm system isn't functioning as it should, run a quick series general troubleshooting diagnostics to check the device.
- Find the user manual you need for your home appliance products and more at ManualsOnline. Free Nighthawk Carbon Monoxide Alarm User Manuals ManualsOnline.com Go.
- Nighthawk Carbon Monoxide Alarm AC Powered, Plug-In with Battery Backup and Digital Display. Part Number 900-0234. Model KN-COP-DP-LS. The Nighthawk 900-0234 AC Powered, Plug-In carbon monoxide alarm with battery backup and digital display is an easy to install unit that provides reliable protection against the dangers of carbon monoxide.
- Download free Nighthawk KN-COPP-3 Carbon Monoxide Alarm; user guide. View this user manual, technical guide en online. Save your manuals to view later on your computer.
- Technical Spec. The Kidde KN-COP-DP is an AC powered, plug-in carbon monoxide alarm that can be installed easily in any standard wall outlet. The KN-COP-DP uses advanced technology to monitor for carbon monoxide levels in your home and features a NighthawkTM, electrochemical sensor, the world's most accurate carbon monoxide sensing technology.
- Easy to install and monitor, the Kidde Nighthawk KN-COPP-B-LP battery-operated carbon monoxide alarm with digital display provides reliable protection against the dangers of carbon monoxide. Its backlit digital display shows the current carbon monoxide (CO) level at a glance, and it displays every 15 seconds.
Nighthawk Carbon Monoxide Alarm
AC Powered, Plug-In with Battery Backup
Part Number 900-0235
Model KN-COB-DP-LS
Description
The Nighthawk 900-0235 AC Powered, Plug-In carbon
monoxide alarm with battery backup is an easy to
install unit that provides reliable protection against the
dangers of carbon monoxide. Written information and
instruction make this unit’s operation easy to under-
stand for anyone. The Nighthawk AC/DC Basic alarm
has a small, sleek design that is suitable for all living
areas and has a 7-year limited warranty.
Consumer Benefits
The Nighthawk 900-0235 provides you and your fam-
ily with a loud warning signal against the dangers of
elevated carbon monoxide levels in your home. The
battery backup feature provides continuous monitoring
of CO levels, even during power outages when AC-only
units are not providing protection. The Nighthawk CO
alarm has a 7-year product life, providing 40% longer
protection than other CO alarms.
Tamper Resist Feature
Unit alerts you if it has been unplugged
or has come loose from the outlet.
Two LED’s
Red – Illuminates when in alarm mode.
Green – AC power is present, normal operation.
Test/Reset Button
Tests CO alarm circuit operation and allows
you to immediately silence the alarm.
End of Life Alarm
Alerts user to replace CO alarm after
7-years of operation.
40% LONGER LIFE THAN
OTHER CO ALARMS
NEW
LONGLIFE:
UL
SIGNALING
LISTED
2
*Based on accuracy claims of major manufacturers
NIGHTHAWK
TECHNOLOGY
Worldís Most Accurate
Carbon Monoxide Alarm*
TM
Features and Benefits
• Tamper Resist Feature – Unit goes into constant
alarm mode if it has been unplugged or has come
loose from the outlet.
• 9V Battery Backup – Provides continuous protection
even during power outages.
• Test/Reset Button – Tests the unit for proper
operation. Resets the Carbon Monoxide alarm.
• 7-Year End of Life Warning – Alerts user to replace
CO alarm after 7-years of operation. (40% longer
than other CO alarms)
• UL Listed – Lifelong Warranty
AC Powered, Plug-In
Carbon Monoxide Alarm
• Part Number 900-0056 • KN-COP-DP
Digital Display
Displays the level of carbon monoxide the unit is sensing.
The unit updates this reading every 15 seconds.
Test/Reset Button
Tests units electronic circuitry and horn and resets the unit during alarm.
Peak Level Button
Displays the peak CO level recorded by the alarm since it was last reset or unplugged.
NEW Alerts user to replace CO alarm
FEATURE: after 7 years of operation
NIGHTHAWKTM
TECHNOLOGY
Most Accurate Carbon Monoxide Alarm*
Description
The Kidde 900-0056 is an AC powered, plug-in carbon monoxide alarm that can be installed easily in any standard wall outlet. The 900-0056 uses advanced technology to monitor for carbon monoxide levels in your home and features a NighthawkTM, electrochemical sensor,
the world’s most accurate carbon monoxide sensing technology*. The digital display feature allows for easy viewing of carbon monoxide levels.
Consumer Benefits
The Kidde 900-0056 AC powered, plug-in carbon monoxide alarm provides you and your family a warning signal against the dangers of carbon monoxide levels in your home. This alarm is easily installed in any of your AC wall outlets. The digital display feature allows for easy viewing of carbon monoxide levels from 30-999PPM (parts per million). The 900-0056 is UL listed and offers a 5-year limited warranty.
Features and Benefits
•Digital Display – Displays the level of carbon monoxide the unit is sensing. The unit updates this reading every 15 seconds.
• Peak Level Displays the peak CO level
recorded by the alarm since it was last reset or unplugged.
•Test Button – unit’s electronic circuitry and horn and resets the unit during alarm.
AC Powered, Plug-In
Carbon Monoxide Alarm
Architectural and Engineering
Specifications
The carbon monoxide alarm shall be Kidde Unit Number KN-COP- DP (part number 900-0056) or approved equal. It shall be powered by a 120VAC, 60 Hz source. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operation range shall be 5% - 95% relative humidity.
The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL 2034 Single Station Carbon Monoxide Detectors. The unit shall provide accuracy of +/-20% + 15 parts per million (ppm) when reading CO concentration levels.
What Is Carbon Monoxide Alarm
The alarm shall include an attached plug that can be installed in any outlet following the UL/NFPA/Manufacturer’s recommended guidelines. The plug shall be capable of being rotated so the alarm remains vertical independent of whether the electrical socket is mounted vertically or horizontally.
The unit shall incorporate a digital display that meets the sensitivity requirements of UL 2034. The display will identify the levels of CO in parts per million (ppm) once that level reaches 30ppm (i.e.:
“abnormal” levels). The display will have a red dot in the lower right corner that will blink to indicate the normal operation.
The alarm shall include a test button that will electronically simulate the presence of CO and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation.
The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding level of CO.
The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. When the unit detects carbon monoxide, the alarm pattern will be four (4) short beeps – followed by five (5) seconds of silence – followed by four (4) short beeps. A number reading will appear on the digital display identifying the CO concentration (in ppm).
*Based on accuracy claims of major manufacturers
Part Number 900-0056
Unit Number KN-COP-DP
The unit shall include a peak level memory feature that will store the peak CO level sensed since the unit was last reset. The peak CO level stored in the unit’s memory shall be displayed (in ppm) on the digital display by pressing the appropriate button on the unit. The memory shall also be capable of being reset.
The unit shall be listed to UL 2034. It shall also include a 5-year manufacturer’s limited warranty.
Technical Specifications
Part Number: | 900-0056 | ||||||||||||
Unit Number: | KN-COP-DP | ||||||||||||
UPC Number: | 7-84608-00560-1 | ||||||||||||
Power Source: | 120VAC | ||||||||||||
Sensor: | Electrochemical | ||||||||||||
Audio Alarm: | 85dB at 10ft | ||||||||||||
Temperature Range: | 40˚F (4.4˚C) to 100˚F (37.8˚C) | ||||||||||||
Humidity Range: | Up to 95% relative humidity (RH) | ||||||||||||
Size: | 5.65”L x 3.25”W x 1.9”H | ||||||||||||
Weight: | 1lb | ||||||||||||
Interconnects: | No | ||||||||||||
Wiring: | Plug-In | ||||||||||||
LED: | Displays CO concentration in PPM | ||||||||||||
Warranty: | 5 year limited | ||||||||||||
3.25' | 1.9' |
5.65'
Ordering Information
Carbon Monoxide Alarm Beeping
Clam Shell UPC: 7-84908-00560-1
Part | Dimensions | Case/ | Layers/ | Skid | |||
Number | I 2 of 5 | Pack Quantity | (w x d x h inches) | Weight | Skid | Skid | Weight |
900-0056** | N/A | Individual | 7 x 2.5 x 10.75 | 1lb | N/A | N/A | N/A |
900-0056-02 | 107 84908 00560 8 | PDQ (2 units) | 7.75 x 6 x 11.75 | 2lbs | 105 | 3 | 210lbs |
900-0056-07 | 207 84908 00560 5 | Master Pack (4 units) | 7.75 x 11.5 x 12 | 4lbs | 80 | 4 | 320lbs |
900-0056-012 | 307 84908 00560 2 | Cut Case (12 units) | 15 x 18 x 12 | 12lbs | 18 | 3 | 216lbs |
900-0056-036 | 407 84908 00560 9 | Power Tower (36 units) | 20 x 24 x 50 (incl. pallet) | 36lbs | 3 | 3 | 108lbs |
Carbon Monoxide Alarm Chirping
**Not for sale by individual unit
1 | 2 | 4 | 12 | 36 |
UNIT | PDQ | MASTER PACK | CUT CASE | POWER TOWER |
Nighthawk Kn-cop-dp Carbon Monoxide Alarm User Manual Instructions
Distributed by:
1394 South Third Street, Mebane NC 27302
1-800-880-6788 • www.kiddeus.com