Pc1616 Pc1832 Pc1864 User Manual V4.5 And Higher

  1. User Manual Template
  2. Pc1616 Pc1832 Pc1864 User Manual V4.5 And Higher Student
  3. User Manual Pdf

WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the malufacturer. The entire manual should be carefully read. PC1616/PC1832/PC1864 User Manual PavverSeries ™ SECURITY SYSTEM v4.6 and higher. DSC (Digital Security Controls) is a world leader in electronic security. Since the company’s genesis, the experts at DSC have been leading the way. View and Download Dsc PowerSeries PC1616 user manual online. V4.3 Security System. PowerSeries PC1616 Control Panel pdf manual download. Also for: Powerseries pc1832, Powerseries pc1864. WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. PC1616/PC1832/PC1864 User Manual. View and Download DSC PowerSeries PC1616 user manual online. V4.6 and higher Security System. PowerSeries PC1616 Control Panel pdf manual download. Also for: Powerseries pc1832, Powerseries pc1864. DSC POWERSERIES PC1616 User Manual. Trouble cause troubleshooting. DSC Safety.

Advertising

[005] System Times

This section programs the entry and exit delays for the control panel.
After entering section [005] press [1] to select partition 1.
Enter the 3-digit delay time for Delay 1 type zones, Delay 2 type zones
followed by the exit delay time. Press [#] to exit the sub-menu and
return to regular programming.

NOTE: For SIA FAR Installations, the Exit Delay must be within the
range of 045-255 seconds (Default 60 seconds). If the Exit Delay is
silent (Section 14, Option 6 or Stay Function Key Arming) the exit
delay must be twice the programmed value but must not exceed 255
seconds (i.e., 090-255 seconds).

NOTE: For UL Installations, the Entry Delay plus the Communications
Delay must not exceed 60 seconds.

NOTE: Exit Time Restart shall be disabled when the panel is used in
combination with T-Link TL250/TL300.

[006] Installer Code
Enter a new 6-digit Installer Code

[007] Master Code
Enter a new 6-digit Master Code

[008] Maintenance Code
Enter a new 6-digit Maintenance Code

[009-010] PGM Programming
PGMs 3&4 apply to PC1864 only

[013] – First System Option Code

The first two toggle options in this section are used to determine what
type of EOL resistors are being used, toggle option [1] to determine if
normally-closed or EOL resistors are being used and option [2] to
determine if single or double EOL resistors are being used. Configure

the options as required and press [#] to exit

.

[015] – Third System Option Code

This section is used to determine if the Panic keys on the keypads will
be audible or silent (toggle option [2]) and if phone line supervision is
enabled or disabled (toggle option [7]). Configure the options as

required and press [#] to exit.

[018] Cross Zone/Police Code

NOTE: The panel uses the cross zoning attribute for Burglary Verifica-
tion. This feature requires two or more trips on a zone(s) specified as
‘cross zones’ within a specified time before starting an alarm sequence
(See Section[101] Option 3, page 33 of the Reference Manual).

[165] Maximum Dialing Attempts to each Phone Number
This section programs the number of Dialing Attempts. Enter a
3-digit. For UL Listed Installations 5-10 Dialing attempts are
required
.

[301] First Telephone Number (32-digits)

Program the central station phone number or CAA for T-LINK.
In addition to the standard digits [0] - [9], Hex digits may also be
required (Refer to the “Programming Decimal and Hexadecimal (HEX)
Data” at the beginning of this section).

[304] Call Waiting Cancel String (6 Digits)
Program Unused digits with Hex F

[005]

[01] Partition 1 Entry/Exit Times

User Manual Template

Def

Enter 3 digits [[001]-[255]

030 I___II___II___I

*045 I___II___II___I

**120 I___II___II___I

Entry Delay 1
Entry Delay 2
Exit Delay 1

Valid entries: [030] to [255]
Valid entries: [030] to [255]
Valid entries: [060] to [255]

*Entry Delay 2 Default is 030 for SIA CP-01 Installations
**Exit Delay 1 Default is 060 for SIA CP-01 Installations

Default 555555

I___II___II___II___II___II___I

Default 123456

I___II___II___II___II___II___I

Default AAAAAA

I___II___II___II___II___II___I

[009]

Main Board PGM Output Programming

Def

Enter 2 digits [[01]-[32]

19
10
01
01

I___II___I
I___II___I
I___II___I
I___II___I

PGM 1
PGM 2
PGM 3
PGM 4

Section [009]
Section [009]
Section [010] ...... PC1864 Only
Section [010] ...... PC1864 Only

01 Fire & Burglary Output
02 Not Used
03 Sensor Reset (

72)

04 2-Wire Smoke (PGM2 Only)
05 Armed Status)
06 Ready to Arm
07 Keypad buzzer follow mode
08 Courtesy Pulse
09 System Trouble output (with Trouble

Options)

10 System Event (with Event Options)
11 System Tamper (All Sources)
12 TLM and Alarm
13 Kiss-off Output
14 Ground Start Pulse
15 Remote Operation
16 Future Use

17 Away Armed Status
18 Stay Armed Status
19 Command Output#1 (

71)

20 Command Output#1 (

72)

21 Command Output#1 (

73)

22 Command Output#1 (

74)

23 24-hr Silent Input
24 24-hr Audible Alarm
25 Delayed Fire & Burglary Output
26 Battery Test Output
27 Police Code Output
28 Holdup Output
29 Zone Follower Inverted Output
30Partition Status Alarm Memory

Output

31 Alternate Communications
32 Open After Alarm (Abort Code)

Opt

Default

Description

1

I__I

ON

Normally Closed loops

OFF

End-of-line Resistors

2

I__I

ON

Double End-of-Line Resistors

OFF

Single End-of-Line Resistors

8

I__I

ON

Temporal Three Fire Signal

OFF

Standard Pulsed Fire Signal.

Opt

Default

Description

2

I__I

ON

[P] Key Audible (Bell/Beeps) loops

OFF

[P] Key Silent

7

I__I

ON

TLM Enabled

OFF

TLM Disabled

Opt

Default

Description

6

I__I

ON

Cross Zoning Enabled

Pc1616 Pc1832 Pc1864 User Manual V4.5 And Higher Student

OFF

Police Code is Enabled

[165]

Maximum Dialing Attempts to each Phone

Def

Enter 3 digits [[001]-[005]

005

User

I___II___II___I

Valid entries: [001] to [005]

I

D

II___II___II___II___II___II___II___II___II___II___II___II___II___II___II___I

I___II___II___II___II___II___II___II___II___II___II___II___II___II___II___II___

Default DB70EF [Hex]

I___II___II___II___II___II___I

Advertising
This manual is related to the following products:
Popular Brands

User Manual Pdf

Popular manuals